SPECIFICATIONS
INTENDED USES
1. These engine generator sets have been designed for
portable use. Receptacles are provided in the con-
trol panel on the generator for you to plug in your
loads (portable appliances and tools). These gener-
ators are designed with full power capabilities. See
unit capabilities for further explanation.
2. These units require large quantities of fresh air for
cooling of both the engine and the generator. Fresh
air is drawn from both the engine end and the gen-
erator end and is exhausted at the center of the unit.
For safety, long life and adequate performance,
these units should never be run in small compart-
ments without positive fresh air flow.
MODEL
Generator
Surge Watts
Continuous Watts
AC Volts
AC
AMPS
DC Volts
DC
AMPS
Receptacles
NEMA 5-15 (120V)
N EMA 5-30 (1 20V)
12 Volt DC
Engine
Size
Model
TY pe
Fuel Capacity
Fuel Consumption
full Load
Starting System
Stop System
Low Oil Shutdown
Muffler
Complete Unit
Weight (dry)
Dimensions
LxWxH
Owner Must
Provide
Fuel
Oil Type
Oil Capacity
RESTRICTED USES
1. DO NOT remove from the cradle assembly. Remov-
al of the generator from the cradle assembly. may
cause excessive vibration and damage to the engine
generator set.
2. DO NOT install and operate these portable gener-
ators in small compartment.
(i.e. generator compart-
ment of vehicles, motor homes or travel trailers)
These compartments will not allow enough free flow
fresh air to reach the engine generator set for cool-
ing and will allow the unit to overheat damaging both
DX3200 CSADX3200
3200 3200
2800 2800
120 120
23.3 23.3
12 12
10 10
4
2
1
1 1
5H P 5H P
FA21 0 FA21 0
See Engine For Type
3/4
GAL
3/4
GAL
0.75 glhr 0.75 glhr
Recoil
Switch on Engine Shroud
Standard
Standard Muffler with Spark
Arrestor
99
LBS
99
LBS
24x15~14 24x1 5x1
4
Unleaded Gasoline
SAE30 SC Class. See engine
manual for additional info.
.64 US qt. .64 US qt.
the engine and the generator. Small compartments
will also develop hot spots where there is very little
air flow and may cause a fire.
3. DO NOT attempt to operate this unit at 50 cycles.
'"'
These units are designed and governed to operate
at 60 Cycles only. Special units are available for 50
cycle operation.
UNIT CAPABILITIES
1. Generator Connections
-
These generators are equip-
ped with a single output power winding. This design
will give the owner full rated generator output from
a SINGLE 120 volt outlet.
The battery charging circuit on the DX3200 is a
center tapped off the standard 120 volt winding. On
the
CSADX3200 the battery charging circuit is
separate winding on the armature. This output is
then run through a half wave bridge rectifier where
the current is changed from AC to pulsing DC cur-
rent. The open circuit charging voltage as measured
with a DC meter or a volt-ohm meter will read ap-
proximately seven
(7)
volts. The peak voltage will be
over 16 volts in order to charge the battery. When
the generator is connected to a 12 volt battery, the
battery level voltage will immediately increase about
0.5 volts showing that the battery is being charged.
A DC ammeter in series with the generator output
will indicate a current reading approximately equal
to the DC nameplate rating if the battery is dis-
charged.
FIG B1
The following currents (measured in amps) are pro-
duced at 120 volts and 240 volts for models shown.
AMPS
@
120 VOLT 12 VOLT
RECEPTACLE
ID
MODEL
DX3200
CSADX3200 23.3